Abstract—A current source inverter (CSI) requires a capacitor filter for the commutation of switching device as well as for attenuating switching harmonics. Hence, the CSI-fed ac machine has a second-order system in the continuous time domain. This paper presents a design methodology for the closed-loop current controller of the CSI-fed ac machine drive system. A multiloop current controller design using a pole/zero cancellation method is employed with a transfer function matrix. To decouple the crosscoupling terms which cause mutual interferences between the dand q-axes in the synchronous reference frame, two types of controller are proposed and implemented using different decoupling method. Additionally, active damping methods are incorporated to enhance the stability of the system. A stability analysis in discretetime domain is investigated to verify the feasibility of the proposed closed-loop current controller. To evaluate the effectiveness of the proposed current controller, computer simulations and experimental tests were performed and the results are discussed.
Mechanical project in trichy, ieee 2013 power electronics projects, ieee 2013 matlab simulation project, Matlab Image processing project, ieee project for eee, Ieee project for ece, ieee 2013 embedded project, mini project for all final year engineering, diploma, b.e, m.e students in Chennai and trichy
Subscribe to:
Post Comments (Atom)
No comments: